| Integrated connection type |
Duplex SC fiber optic Shielded RJ45 copper cable
|
| Transmission support medium |
Twisted shielded pairs cable CAT 5E for copper cable Multimode optical fiber for fiber optic
|
| Maximum cable distance between devices |
100 m copper cable
|
| Attenuation |
11 dB (62.2/125 µm) 8 dB (50/125 µm)
|
| Ethernet service |
Multicast filtering SNTP client SMTP V3 IGMP Snooping Configuration via web server Secure port Data stream control VLAN Rapid Scanning Tree Protocol (RSTP) Priority port FDR
|
| Maximum number of switches in a ring |
50
|
| Redundancy |
Redundant power supplies Ring coupling Redundant single ring
|
| [Us] rated supply voltage |
12...48 V
|
| Supply voltage limits |
10…60 V DC SELV
|
| Power consumption in W |
12 W
|
| Electrical connection |
2 removable connectors 2 ways power supply
|
| Mounting support |
35 mm symmetrical DIN rail
|
| Marking |
CE
|
| Local signalling |
2 LEDsP1 P2 power supplies: 1 LEDfault: 1 LEDring manager: 1 LEDstand-by: 1 LED per channelcopper port activity: 1 LED per channelcopper port status:
|
| Alarm output |
2 voltfree contact 1 A
|
| Alarm function |
Power supply fault High temperature Data link status
|
| Ethernet cabling system |
TF switches
|
| Width |
120 mm
|
| Height |
137 mm
|
| Depth |
115 mm
|
| Net weight |
1 kg |